Welcome, Guest
Abstract_id
Print Version
Having trouble downloading?

Internet Explorer Information Bar
Internet Explorer blocks automatic downloads by default, instead displaying an "Information Bar" at the top of the page. (example)

Click on the bar and select "Download file" or follow these simple instructions to change your settings.

Pop-up blocker software
You can hold down the CTRL key when selecting Download to bypass your pop-up blocker.

You may also configure your pop-up blocker to allow EPRI.com and my.epri.com to open new windows.

Recommended Software
EPRI recommends using Internet Explorer 7 and Adobe Reader version 8 for best performance.

Get Internet Explorer 7 - free download
Get Adobe reader - free download
 
Support Services

EPRI Customer Assistance
Center (CAC):

800-313-3774 or 650-855-2121
Option 4
askepri@epri.com

Hours of Operation:
8:00 AM - 7:00 PM Eastern Time
(GMT-5)

Order and Conference Center:
800-313-3774 or 650-855-2121
Option 2
orders@epri.com

EPRI: Program on Technology Innovation:<br> Room at the Mountain
  Program on Technology Innovation:
Room at the Mountain
 

 
Product ID: 1015046 Sector Name: Nuclear
Date Published: 6/29/2007 Document Type: Technical Report
File size: 10.73 MB File Type: Adobe PDF (.pdf)
  


 
   Full list price:No Charge   
 
    This Product is publicly available.

 
  Abstract  
  Projected expansion of nuclear power beyond the year 2014 will result in the need for commercial spent nuclear fuel (CSNF) management options in addition to the currently legislated CSNF storage capacity at the proposed Yucca Mountain geological repository. At present, 70,000 MTHM of storage capacity has been authorized, with a projection that 63,000 MTHM would be used for CSNF. This report extends preliminary analyses of the maximum physical capacity of the Yucca Mountain repository, presented in EPRI report 1013523. EPRI is confident that at least four times the current CSNF limit (~260,000 MTHM) and possibly upwards of nine times the limit (~570,000 MTHM) could be emplaced with additional site characterization.  
   
   
   
  Objective  
  The purpose of the analyses presented in this report is to confirm the feasibility, performance, and robust safety of expanded Yucca Mountain capacity options. The analyses also provide an initial cost basis by which to compare these expanded capacity options with alternative management approaches, such as a second repository, extended interim storage, or reprocessing.  
  Approach  
  The report presents the results of analyses in four areas:
  • Thermal, hydrological, and mechanical analyses involving comprehensive fracture-matrix interaction and application of three-dimensional models to the Yucca Mountain site
  • Ventilation and mining technology suitable for expanding the capacity at Yucca Mountain
  • Long-term performance and safety of an expanded capacity repository at Yucca Mountain
  • Cost analysis of expanding the CSNF capacity at Yucca Mountain
  •  
      Results  
      EPRI has taken the lead in examining Yucca Mountain expansion options for CSNF disposal, focusing on three key strategies, as follows:
  • Option 1: Expanding the current line-load/high-temperature operating mode (HTOM) design over the maximum rock area at Yucca Mountain considered suitable for spent fuel disposal by the DOE Yucca Mountain Project
  • Option 2: Constructing a “multi-level” set of emplacement drifts in which the exact same geometrical configuration of emplacement drifts of the line-load/HTOM design would be built at three different levels
  • Option 3: Constructing a single-level repository by grouping three emplacement drifts (“grouped drift”), in which two additional emplacement drifts would be positioned at 20-m horizontal offsets on either side of each of the currently planned drifts

  • Option 1 can be combined with Option 2 or 3 to provide for even greater Yucca Mountain capacity.

    This report is organized as follows. Section 2 presents the results of comprehensive two-dimensional and full three-dimensional models to analyze thermal, hydrological, and mechanical effects of Options 2 and 3, which were formerly evaluated using simple one- and two-dimensional models. Impacts on the spatial and temporal redistribution of water vapor and condensed water are evaluated, with particular emphasis on how liquid water, initially driven away by radiogenic heating, eventually condenses and drains around but not through the emplacement tunnels. Possible coupling among thermal, hydrological, and mechanical processes during the initial thermal heating period are also analyzed. Section 3 explores the engineering feasibility of constructing multiple emplacement drifts for Options 2 and 3, with a discussion of impacts on ventilation. The potential impacts on long-term safety from positioning multiple emplacement drifts within the existing disposal blocks at Yucca Mountain are discussed in Section 4. A preliminary cost analysis is presented in Section 5 to provide an initial basis for comparing expanded capacity options with other waste management approaches. Section 6 provides a summary of results and recommendations based on the reported analyses.

      Application, Value and Use  
      The advantage of the proposed expansion designs examined in this report is that DOE can proceed without delay into licensing with its current design for the first 70,000 MTHM of high-level waste and CSNF disposal. Concurrent R&D would establish the technical bases necessary for future repository expansion.  
      EPRI Perspective  
      If all U.S. operating commercial nuclear reactors each operated for a total of 60 years, approximately 140,000 MTHM of CSNF would be available for disposal, including the existing CSNF from reactors previously shut down. This analysis shows that it is possible for the Yucca Mountain repository to store not only all of the waste from existing U.S. nuclear power plants, but also waste produced from a significantly expanded U.S. nuclear power plant fleet for at least several decades. Even if the United States decides to close the nuclear fuel cycle by introducing reprocessing along with the use of advanced reactors, Yucca Mountain could, if necessary, serve as the only CSNF and high level radioactive waste repository needed for at least several decades into the future, if not longer. This potential for expanded Yucca Mountain capacity would allow time for the necessary R&D to accomplish a full-scale and economically competitive closed fuel cycle.  
      Program  
      2007 Yucca Mountain Regulatory Issues  
      Keywords  
      Spent Nuclear Fuel
    Yucca Mountain
    High Level Radioactive Waste
     
      Note:  
      EPRI Customer Assistance Center
    (800) 313-3774
    email:askepri@epri.com
     
      Direct URL
    http://my.epri.com/portal/server.pt?Abstract_id=000000000001015046
     
    Careers  | Contact Us  | Email This Page  | Copyright Policy | Privacy Statement  | Terms of Use | Site Map
    EPRI 3420 Hillview Avenue, Palo Alto, California 94304
    © Electric Power Research Institute, Inc. 2001- All rights reserved